aINTERNATIONAL
asdasaasdasdasdSEMICONDUCTOR
dsaasdasdasdaddsaasdasdasdasdCONFERENCEdaa


 



 

Tuesday, October 14, 17:30–19:00, Room “C”

MEMSBIO  MEMS–TECHNOLOGY
&  APPLICATIONS  2
Session Mb2: Poster presentations

Joint session with the
INTEGRAMplus Project (IP⁄FP6)

Chair:
I. Kleps, IMT-Bucharest, Romania
C. Moldovan, IMT-Bucharest, Romania

 

Mb2. 1

MEASUREMENTS OF THE ELECTRICAL CHARACTERISTICS IN DC AND AC REGIME FOR AN EPINEPHRINE BOI DEVICE, C. Ravariu1, C. Podaru2, E. Manea2, D.N. Vizireanu1, A. Bondarciuc3, A. Rusu1, F. Ravariu2, 1“Politehnica” Univ. of Bucharest, 2IMT-Bucharest, 3Colentina Hospital, Bucharest, Romania.

Mb2. 2

MIXED–MONOLAYERS WITH ALKANE THIOL ON GOLD AS SUBSTRATES FOR MICROARRAY APPLICATIONS,C.-M. Mihailescu1, D. Stan2, L. Ruta1, I. Baciu1, C. Moldovan3, V. Schiopu3, M. Simion3, R. Gavrila3, 1Univ. of Bucharest, 2DDS Diagnostic, Bucharest, 3IMT-Bucharest, Romania.

Mb2. 3

SIMULATION, DESIGN AND MICRO­FABRICATION OF MULTICHANNEL MICROPROBE FOR BIOELECTRICAL SIGNALS RECORDING, B. Firtat1, R. Iosub1, D. Necula1, E. Franti1, F. Babarada2, C. Moldovan2, F. Lazo3, IMT-Bucharest, 2“Politehnica” Univ. of Bucharest, 3Inst. of Artificial Intelligence, Bucharest, Romania.

Mb2. 4

Silicon 3D Structuring by anodization, F. Craciunoiu, A. Dinescu, A. Bragaru, IMT-Bucharest, Romania.

Mb2. 5

A HIGH PERFORMANCE PZT TYPE MATERIAL USED AS SENSOR FOR AN AUDIO HIGH FREQUENCY PIEZOELECTRIC SIREN, C. Miclea, C. Tanasoiu, A. Iuga, I. Spanulescu*, C.F. Miclea, C. Plavitu*, L. Amarande,
M. Cioangher, L. Trupina, C.T. Miclea*, T. Tanasoiu*
, National Inst. for R&D Materials Physics, Bucharest, *Hyperion Univ., Bucharest, Romania.

Mb2. 6

TECHNOLOGICAL FABRICATION OF THE HUMIDITY SENSORS ON NANOSTRUC­TURATED MEMBRANE, A. Bragaru, M. Miu, F. Craciunoiu, I. Kleps, M. Simion, T. Ignat, IMT-Bucharest, Romania.

Mb2. 7

effect of Anomalous Scattering and K-fluroscence reabsorption on the performance of selenium, A. Sultana, A. Reznik*, K.S. Karim, J.A. Rowlands*, Univ. of Waterloo, *Imaging Research, Toronto, Canada.

Mb2. 8

PREPARATION OF SERS-ACTIVE POROUS GOLD SUBSTRATE, T. Ignat, I. Kleps, M. Miu, F. Craciunoiu, A. Bragaru, M. Simion, IMT-Bucharest, Romania.

Mb2. 9

BIOHYBRID SURFACE PREPARATION FOR PROTEIN/DNA MICROARRAY APPLICATIONS, M. Simion1, L. Ruta2,
I. Kleps1, C. Mihailescu3, A. Bragaru1, M. Miu1, T. Ignat1
, 1IMT-Bucharest, 2Univ. of Bucharest, 3DDS Diagnostic, Bucharest, Romania.

Mb2. 10

A NEW DESIGN BASED ON ELECTRO-THERMALLY ACTUATION FOR AN SU-8 MICROGRIPPER, R. Voicu, R. Muller, L. Eftime, IMT-Bucharest, Romania.

Mb2. 11

THE NOISE OF MOS MAGNETIC MICROSENSORS STRUCTURES, C. Panait, G. Caruntu, Constantza Maritime Univ., Romania.

20:30   BANQUET – Sinaia Hotel, Restaurant Hall


 
About Us | Site Map | Contact Us |
IMT - Bucharest 32B, Erou Iancu Nicolae Street, R- 077190 , Bucharest, ROMANIA
Mailing address: PO-BOX 38-160, 023573 , Bucharest, ROMANIA; Tel: +40-21-490.82.12; +40-21-490.84.12; +40-21-490.85.83; +40-21 -490.82.03; Fax: +40-21-490.82.38; +40-21-490.85.82